PRODUCT INFORMACTION

Temperature Humidity Test Chambers

If you are interested in this product, you can
Product Name: Temperature Humidity Test Chambers
Product Model: Platinous-Series
Product Exhibitors: 其它品牌
Product Documentation: No Related Documents

Briefing

Temperature & Temerature-Humidity Chambers » Platinous-Series Environmental Test Chambers


Temperature Humidity Test Chambers  Details of

Temperature Humidity Test Chambers /Temperature Chambers / Humidity Chambers

The next global generation of Environmental Test Chambers


The P Series offer a flexibility of choice to meet your needs just like a custom-made chamber. Numerous features, network solutions and dramatically eco. One of these models is made for you.



Hongzhan's P-Series Temperature and Temperature/Humidity Test Chambers provide high-performance testing over a wide range of applications. From prototyping to durability testing to product component screening, the P-Series is designed to meet quality standards while offering flexibility, uniformity, and control accuracy for cost-effective testing.

P-Series Test Chambers perform both high and low temperature tests. Many of these chambers have a temperature range of -68 to +180°C (-94 to +356°F). Temperature/Humidity models are equipped with a reliable, accurate, and efficient full range humidity system capable of simulating conditions from 10 to 98% RH. Hermetically sealed compressors provide moderate temperature change rates while allowing the chamber to consume less power than comparable chambers. Advanced features such as an electronic humidity sensor and product temperature control help reduce maintenance and test time.

*Platinous series high temperature (heat) test equipment characteristics
High strength and high reliability of the structure design to ensure the high reliability of equipment;
The studio material is SUS304 stainless steel corrosion resistance, thermal fatigue, strong function, long service life;
Polyurethane foam insulation material - high density that minimizes heat loss;
Surface spray treatment - ensure lasting anticorrosion function and appearance of the life of the equipment;
High strength heat-resistant silicone rubber seal, ensure the high sealing equipment door;
A variety of optional features (test hole, recorder, water purification system) to ensure the needs of users of various functions and test;
A large area of electric defrosting observation window, the interior lighting, can provide a good look;
Environmental protection type refrigerant - ensure equipment more in line with your request of environmental protection;
*Platinous series high temperature (heat) test box can be customized according to user requirements size / index / custom customized matching function


*Platinous series high temperature (heat) test box temperature control
Can achieve the temperature constant control and program control;
The whole data recorder (optional) recording can be achieved in the testing process and back;
Each motor is configured over current protection (overheating) / heater set short-circuit protection, ensure the high reliability of air and heating equipment during operation;
USB interface, Ethernet communication function, the communications equipment and software extensions satisfy the needs of customers;
The refrigeration control mode of the international popular 0%~100%, can automatically adjust the compressor power, reduce the heat balance energy consumption compared with the traditional 30% temperature control mode;
Refrigeration and electric key parts adopt international famous brand products, the overall quality of the equipment has been improved and guaranteed;
*Platinous series high temperature (heat) test equipment meet the following criteria
The condition of GB/T 10592 -2008 high low temperature test box
The condition of GB/T 10586 -2006 damp heat test box
GB/T 2423.1-2008 environmental testing for electric and electronic products part second: Test methods - Test A: low temperature
GB/T 2423.2-2008 environmental testing for electric and electronic products part second: Test methods - Test B: high temperature
GB/T 2423.3-2006 environmental testing for electric and electronic products part second: Test methods - Test Cab: Damp heat test
GB/T 2423.4-2008 environmental testing for electric and electronic products part second: Test methods - Test Db: alternating (12h + 12h)
GB/T 5170.1-2008, general electric and electronic products environmental testing equipment testing method
GJB 150.3A-2009 test method for laboratory environment of military equipment - Part third: high temperature test
GJB 150.4A-2009 test method for laboratory environment of military equipment - Part fourth: test at low temperature
GJB 150.9A-2009 test method for laboratory environment of military equipment - Part ninth: Damp heat test





 
 
Platinous series of high and low temperature test box; high and low temperature test box; the main technical indexes of alternating high and low temperature test box
Type 1
PR-80
PR-150
PR-225
PR-408
PR-800
PL-80
PL-150
PL-225
PL-408
PL-800
PSL-80
PSL-150
PSL-225
PSL-408
PSL-800
The nominal capacity (liters)
Eighty
One hundred and fifty
Two hundred and twenty-five
Four hundred and eight
Eight hundred
Eighty
One hundred and fifty
Two hundred and twenty-five
Four hundred and eight
Eight hundred
Eighty
One hundred and fifty
Two hundred and twenty-five
Four hundred and eight
Eight hundred
nature
can
*
Two
temperature range
-20 C ~ +150
-40 C ~ +150
-70 C ~ +150
Humidity range
Twenty ~ 98%RH, 10 ~ 85 DEG C
Temperature fluctuation
+ 0.5 C
Temperature deviation
+ 2 C
Humidity deviation
(>75%RH + 3.0%RH When) + 5.0%RH (less than 75%RH)
Heating time
-20-->+150 C
-40-->+150 C
-70-->+150 C
 
Less than 60min
Less than 70min
Less than 60min
The cooling time
+20-->-20 C
+20-->-40 C
+20-->-70 C
 
Less than 45min
Less than 60min
Less than 80min
ruler
inch
 
W
Four hundred
Five hundred
Six hundred
Six hundred
One thousand
Four hundred
Five hundred
Six hundred
Six hundred
One thousand
Four hundred
Five hundred
Six hundred
Six hundred
One thousand
The internal size (mm)
H
Five hundred
Six hundred
Seven hundred and fifty
Eight hundred and fifty
One thousand
Five hundred
Six hundred
Seven hundred and fifty
Eight hundred and fifty
One thousand
Five hundred
Six hundred
Seven hundred and fifty
Eight hundred and fifty
One thousand
 
D
Four hundred
Five hundred
Five hundred
Eight hundred
Eight hundred
Four hundred
Five hundred
Five hundred
Eight hundred
Eight hundred
Four hundred
Five hundred
Five hundred
Eight hundred
Eight hundred
 
W
Six hundred
Seven hundred
Nine hundred and eighty
One thousand and eighty
One thousand four hundred and eighty
Six hundred
Seven hundred
Nine hundred and eighty
One thousand and eighty
One thousand four hundred and eighty
Six hundred
Seven hundred
Nine hundred and eighty
One thousand and eighty
One thousand four hundred and eighty
The external size (mm)
H
One thousand four hundred and ninety
One thousand five hundred and ninety
One thousand seven hundred and ninety
One thousand and nine hundred
Two thousand and fifty
One thousand four hundred and ninety
One thousand five hundred and ninety
One thousand seven hundred and ninety
One thousand and nine hundred
Two thousand and fifty
One thousand four hundred and ninety
One thousand five hundred and ninety
One thousand seven hundred and ninety
One thousand and nine hundred
Two thousand and fifty
 
D
Nine hundred and forty-five
One thousand and fifty
One thousand and thirty
One thousand two hundred and forty
Two hundred and forty
Nine hundred and forty-five
One thousand and fifty
One thousand and thirty
One thousand two hundred and forty
One thousand two hundred and forty
Nine hundred and forty-five
One thousand and fifty
One thousand and thirty
One thousand two hundred and forty
One thousand two hundred and forty
The observation window size (mm)
Volume 80 , One hundred and fifty , Two hundred and twenty-five , Four hundred and eight by 450H * 300W; Volume 800 800H * 600W
Temperature and humidity control method
BT (H) C Balanced temperature (humidity) way
 
The use of environmental temperature
+5 C ~ +35
material
material
Shell
Double sided galvanized steel plate, surface spray treatment
The inner body
SUS304 stainless steel plate
Heat insulation
Polyurethane foam and glass fiber
transfer
section
implement
heater
Ni Cr alloy electric heater
Humidifier
Stainless steel sheathed heater (water humidification)
Blower
Centrifugal fan
Refrigeration compressor
Full closed low noise compressor rotor
Cryogen
R404a
R404a/R23
Refrigeration method
Mechanical compression of single stage refrigeration (air or water)
Two yuan mechanical compression cascade refrigeration (air or water)
control
system
implement
Monitor
Seven Inches, 640 * 480 dot matrix, TFT color LCD display
Operation mode
Program mode and setting value
Setting mode
In English menu, touch screen input
Program capacity
Edit: 269 procedures. Each program can be set 50, 3200 cycles (each cycle step maximum 32000 cycles: 269); fixed program; program link. Set value can be set for 999999 hours.
Setting range
Temperature: according to the temperature scope of work equipment adjustment (upper limit +5 C -5 C)
Humidity: 0-100%RH (such as equipment with humidity function)
Display resolution
The temperature of 0.1 DEG C; 0.1min
Humidity: 0.1%RH (such as equipment with humidity function)
input
Three wire automatic compensation PT100
Communication function (optional)
RJ45 Interface, network interface, mobile phone communication can realize local and remote communication function (network communication control, mobile phone communication control function is optional), www.oven.cc software available Chinese simplified Windows 2000 or Windows XP Chinese simplified operating system, COM port and USB port PC occupy a maximum of 254 devices connected; at the same time, the cumulative maximum length of 1200m cable.
control mode
Anti windup PID
   
Curve recording function
With the battery protection RAM, can save equipment set value, sampling value and sampling time. The maximum storage time of 90 days (when the sampling period is 1min).
USB function
With a USB 2G, special software for PC cd. Through the PC machine software test procedure. The test curve of storing records in controller, data is transferred to the USB drive. Display directly through the PC machine and print the test data (/ curve from the controller to dump on the USB curve as picture format can not be modified);
Subsidiary function
The reason, fault alarm and prompt function; power-off protection function; upper and lower temperature protection function; timing function (automatic start and stop automatically); self diagnosis function.
   
for
water
1.
Water supply mode
Lift pump
Water storage tank
Eighty Type 150: 225, built-in water tank 10L; 408, 800: 20L 1 built-in water tank
Water Quality
The resistivity of >500 m.
 
Power Supply
AC220 (1 + 10%) V (50 + 0.5) Hz single-phase two line + ground protection; *AC380 (1 + 10%) V (50 + 0.5) Hz three-phase four wire + ground protection
 
The maximum current (A)
Fourteen
Seventeen
Twenty
Twenty-six
*13.2
Seventeen
Twenty
Twenty-three
*11.8
*17.6
*11.8
*14.6
*17.6
*22
*30.8
 
Power (kw)
Three point two
Three point eight
Four point five
Six
Nine
Three point eight
Four point five
Five point two
Eight
Twelve
Eight
Ten
Twelve
Fifteen
Twenty-one
 
Net weight (kg)
Two hundred and twenty
Two hundred and thirty
Two hundred and seventy-five
Three hundred and five
Four hundred and fifty
Two hundred and thirty
Two hundred and forty
Three hundred
Three hundred and fifty
Four hundred and eighty
Two hundred and sixty
Two hundred and ninety-five
Three hundred and twenty-five
Four hundred and twenty-five
Six hundred and fifty
 
Standard configuration
The observation window 1 (transparent electrothermal film insulating glass), cable hole (diameter 50mm) about 1 each, 2 sets of sample holder, lamp box 1, 1 timers, casters 4, power line 1 (6 meters long), RS-485 interface, the sample power control terminal 1, USB interface 1, 2G 1
 
Safety device
Leakage breaker, dry burning protection (only damp heat), water system protection device (only damp heat), fan motor overheat protection, temperature fuse, control circuit overload short-circuit protector, upper and lower cooling water temperature protection, undervoltage protection relay (only water cooled), compressor overpressure and overcurrent overheating protection, phase sequence protection, condenser fan over-current protection (only air-cooled type)
1. No heat function models were PM ( -20 C), PU ( -40 C), PG ( -70 C) . The 2 room temperature is +25 DEG C, under the condition of no sample measured data.
Technical data of this material are subject to change without notice, Hongzhan Technology Co. Ltd.
 





 

Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!